200W LED Flood Light Manufacturer for Outdoor Projects
VST Lighting is a China-based 200W LED flood light manufacturer supporting distributors, contractors, importers, wholesalers, lighting solution providers, and OEM/ODM partners with reliable high-output outdoor lighting solutions.
Our 200W LED flood lights are designed for parking lots, billboards, building exteriors, loading yards, construction sites, sports areas, industrial yards, security perimeters, commercial plazas, and large outdoor spaces. We focus on project details that matter: strong lumen output, weather protection, stable drivers, heat dissipation, beam control, bracket strength, and export-ready packaging.
Factory-direct China supply
OEM/ODM support available
Flexible MOQ for trials
Aging test before shipment
Outdoor project support
200W LED Flood Lights Built for Wide Coverage and Lower Maintenance
A 200W LED flood light is usually selected when a project needs strong illumination for larger outdoor or semi-outdoor areas. It can be used for parking lots, billboards, factory yards, loading docks, building exteriors, construction sites, sports courts, security perimeters, and commercial open spaces where weaker fixtures cannot provide enough coverage.
For B2B buyers, the sourcing risk is not only choosing the wrong wattage.
If the lumen output is overstated, the site may still have dark zones after installation. If the beam angle is too wide, light may spill into unwanted areas and waste energy. If the beam angle is too narrow, the project may show bright spots and uneven coverage. If the driver is unstable and the fixture starts to flicker, fail early, or struggle with voltage fluctuation, it may be time to replace your flood lights. If the housing does not release heat properly, a 200W flood light can suffer faster lumen depreciation because higher wattage creates higher thermal pressure. If the sealing structure is weak, water can enter through the cable gland, lens seal, screw holes, rear cover, or driver compartment. If packaging is poor, heavy flood lights can arrive with cracked glass, bent brackets, scratched housings, or damaged cables.
That is why a 200W LED flood light should not be purchased only by wattage and price. A serious buyer needs to confirm lumen output, lm/W efficiency, beam angle, reflector design, input voltage, driver grade, surge protection, housing material, heat sink structure, IP rating, IK rating, CCT, CRI, cable entry, bracket strength, mounting method, dimming or sensor options, and export packaging before confirming a bulk order.
VST Lighting supports this process as a 200W LED flood light supplier in China with 10 years of LED lighting production experience. Our management team averages 9 years in the LED lighting business, and our trained production workers understand assembly, inspection, waterproof structure checking, and export packaging for outdoor lighting orders. Our engineers use integrating spheres to check lumen output, color temperature, and CRI. Aging racks help us review fixture stability before shipment. For project buyers who need stronger technical proof, photometric data and third-party LM-79 or LM-80 reports may be available depending on product model and order requirement.
We also understand the real project conditions behind flood lighting selection. A billboard may need a wide beam with stable long-hour output. A parking lot may need glare control and consistent coverage. A loading yard may need strong brackets and higher IP protection. A sports area may need better uniformity and lower flicker risk. A construction site may need rugged housing and safe temporary mounting. A distributor may need private labels, carton marks, and repeatable packaging for local resale.
Your true cost is not only the fixture price. It includes lift rental, installation labor, dark-zone complaints, water-ingress failures, energy waste, replacement trips, damaged goods, delayed handover, and after-sales pressure from your local customer. VST Lighting helps reduce these risks by checking product structure, LED performance, driver matching, optical design, waterproof details, mounting accessories, packaging, and order requirements before mass production.
Highlighted Features of 200w led high bay light

200W LED flood lights provide strong illumination for parking lots, billboards, yards, building exteriors, sports areas, and commercial outdoor spaces.

P-rated housing, sealed glass structure, cable-entry control, and gasket design help reduce water, dust, corrosion, and outdoor failure risk.

Aluminum housing, heat sink design, and matched drivers help manage heat pressure from high-power outdoor operation.

Adjustable brackets, wall mounting, pole support, ground positioning, and project-specific accessories can support different flood lighting layouts.
VST and Its Satisfying Customers
Before choosing a 200W LED flood light supplier, buyers need to see how the factory controls high-power LED modules, driver matching, waterproof structure, optical testing, aging, and export packaging. In our video section, you can review real production lines, LED flood light assembly, aging tests, integrating sphere checks, waterproof structure review, packaging inspection, and customer project feedback.
These videos help contractors, distributors, importers, wholesalers, lighting solution providers, and OEM buyers evaluate VST Lighting with more confidence. You can see how our team handles LED chips, 200W drivers, aluminum housings, tempered glass, reflectors, brackets, cable entry, and export packing before sample approval or bulk ordering.
Applications of 200w LED flood light
Parking lots, car parks, vehicle entrances, and outdoor traffic areas often use 200W LED flood lights where strong, wide-area visibility is needed at night. These projects require stable lumen output, suitable beam angle, glare control, weather protection, and reliable mounting. Buyers should confirm pole height, fixture distance, target lux, IP rating, CCT, and driver stability before ordering. VST Lighting supports contractors and distributors with sample testing, product selection, and export-ready 200W flood light supply for parking projects.
Billboards, shop signs, entrance signs, advertising panels, and commercial display boards need clean, consistent illumination so messages remain visible after dark. A 200W LED flood light can support larger signs when the beam angle, mounting distance, and aiming direction are selected correctly. Buyers should confirm sign size, installation position, CCT, reflector type, cable length, waterproof structure, and bracket adjustability before production. VST Lighting helps sign lighting buyers select practical flood light options for outdoor advertising projects.
Building exteriors, facades, perimeter walls, hotel entrances, office blocks, warehouse fronts, and public facility surfaces may use 200W LED flood lights for security, visibility, and architectural presentation. The right optical design can highlight walls without creating excessive spill light or glare. Buyers should confirm beam distribution, installation height, mounting angle, housing finish, weather exposure, and wiring method before ordering. VST Lighting supports commercial lighting distributors with OEM packaging, sample approval, and consistent batch production.
Loading yards, truck bays, container zones, receiving areas, and logistics entrances need strong lighting for forklift movement, truck alignment, barcode reading, and night operation. A 200W LED flood light can provide useful wide-area brightness when positioned and aimed correctly. Buyers should confirm mounting height, beam angle, vibration exposure, bracket strength, IP rating, surge protection, and cable-entry sealing. VST Lighting supports logistics and warehouse project buyers with product matching, technical communication, and export-safe packaging.
Construction sites, temporary work areas, road projects, repair zones, and outdoor maintenance areas often require high-output flood lighting for night work and site safety. These environments may need rugged housing, adjustable brackets, long cables, safe mounting, and practical voltage options. Buyers should confirm fixture protection, impact risk, cable length, beam angle, operating temperature, and installation method before ordering. VST Lighting can support contractors and importers with 200W LED flood light options for temporary and semi-permanent site lighting.
Outdoor courts, training fields, playgrounds, small stadiums, recreation areas, and multi-purpose sports spaces need flood lights with brightness, uniformity, flicker control, and reduced glare. A 200W LED flood light can support smaller sports areas or targeted zones when optical distribution and mounting height are properly planned. Buyers should confirm target lux, beam angle, CRI, CCT, pole position, and aiming direction before production. VST Lighting helps project buyers review lighting requirements and choose suitable flood light options.
Industrial warehouse lighting for yards, factories, storage areas, outdoor workshops, equipment zones, and warehouse perimeters needs durable fixtures for long-hour operation. These sites may expose flood lights to dust, humidity, vibration, heat, and rough installation handling. A 200W industrial LED flood light should be selected based on driver quality, housing strength, IP rating, surge protection, and bracket stability. VST Lighting supports industrial lighting buyers with sample review, OEM options, technical documentation, and coordinated bulk shipment.
Security fences, gates, storage compounds, factory perimeters, construction boundaries, and outdoor restricted areas often use motion activated flood lights to support patrol teams and surveillance cameras. Proper aiming helps improve visibility without disturbing nearby roads or properties. VST Lighting can support sensor-ready flood light options and stable drivers for security lighting solution providers.
Commercial plazas, service stations, retail courtyards, car dealerships, outdoor display areas, and public entrances need lighting that supports visibility, safety, and professional appearance. A 200W LED flood light can illuminate open areas, display edges, walls, signs, and vehicle zones when the beam angle and fixture layout are correct. Buyers should consider CCT, CRI, glare control, housing finish, bracket strength, and dimming or photocell needs. VST Lighting supports B2B buyers with project-specific selection and private label supply.
- Specification
| Model NO. | VST-FL-200WH |
| Wattage | 200W |
| Size | 459*330*177mm |
| Lumens | 22000~24000lm |
| Working Voltage | AC90~305V |
| LED | Bridgelux |
| Materials | Aluminium alloy housing + Glass cover |
| Body Color | Black |
| Reflector angle | 120° |
| Power Supply | Meanwell |
| Color Temperature | 3000K/4000K/6000K |
| CRI | >75 |
| PF | >0.95 |
| THD | <15% |
| Storage Temperature | -20℃ ~ +65℃ |
| Working Temperature | -20℃ ~ +55℃ |
| Storage Humidity | 10~90% |
| Working Humidity | 10~90% |
| IP Grade | IP65 |
| Lifespan | >30000hrs |
| Warranty | 5 years |
| Certificates | CE RoHS |
| Lead Time | 10 work days for 500pcs |
| Package | Materials : Foam + Carton Carton size: 60*50*45 Carton Capacity : 1pcs/carton Gross weight : 10kg/carton 20ft container load : 180pcs 40ft container load : 400pcs 40ft HQ container load : 480pcs |
VST Lighting is a China-based LED lighting factory located in Shenzhen. We produce and supply 200W LED flood lights, commercial LED flood lights, industrial LED flood lights, LED high bay lights, LED strip lights, LED profiles, LED tube lights, panel lights, triproof lights, downlights, track lights, fluorescent light fixtures, and customized lighting solutions for B2B buyers.
Our factory is located in Shenzhen, China. Shenzhen gives us access to LED chips, driver suppliers, aluminum housing resources, optical parts, sealing materials, packaging vendors, export logistics, and skilled production workers, helping us support international LED flood light buyers more efficiently.
Yes. We can support private labels, product stickers, carton marks, customized packaging, instruction sheets, cable requirements, bracket options, CCT options, sensor options, and market-specific product details. For distributors and importers, OEM support helps build your local brand while keeping factory-direct supply.
We support flexible MOQ for many 200W LED flood light orders. The final MOQ depends on fixture model, housing type, driver option, beam angle, sensor function, packaging request, customization level, and material availability. We try to support sample orders and trial orders for new customers.
Yes. Sample orders are available so you can check lumen output, CCT, CRI, beam angle, driver stability, waterproof structure, housing strength, bracket quality, packaging, and installation compatibility before mass production. Sample approval helps reduce sourcing risk.
For many regular LED lighting orders, production can often be completed within 2–3 weeks after order confirmation and deposit. 200W flood lights with custom drivers, special optics, motion sensors, special packaging, or certification-related requests may need a longer production schedule.
Certification options vary by model, driver, and destination market. Depending on the SKU, options may include CE, RoHS, UL/ETL, CB, VDE, PSE, SAA, C-tick, RCM, or other compliance documents. Please confirm your required documents before ordering.
Yes. We can support product selection and lighting layout guidance based on area size, mounting height, pole position, target lux level, beam angle, and outdoor environment. For some projects, Dialux simulation support may be available after project details are confirmed.
Yes. For dimmable LED flood lights, dimming method, motion sensor, photocell, cable length, plug type, bracket structure, housing finish, CCT, CRI, and packaging can be discussed based on product structure and project requirement. Our team will review feasibility before sample production.
Yes. We support long-term cooperation and respond to product, shipment, installation, waterproof issues, driver concerns, bracket problems, replacement, and maintenance questions. If a problem appears, our team reviews the case based on order details and provides practical support.
Choose a 200W LED flood light by checking the application area, mounting height, target lux, beam angle, lumen output, IP rating, driver quality, surge protection, CCT, CRI, and bracket strength. The right fixture should match the site layout and outdoor environment, not only the wattage.
For most projects, confirm these points before ordering:
Application: parking lot, billboard, loading yard, construction site, sports area, building exterior, or security perimeter
Mounting height: wall, pole, bracket, ground stand, or project-specific structure
Lumen output: confirm actual lm and lm/W
Beam angle: 60°, 90°, 120°, asymmetric, narrow, wide, or project-specific
Input voltage: AC 100–240V, AC 100–277V, AC 220–240V, or market-specific
IP rating: IP65 is common for outdoor flood lights
IK rating: useful where impact risk exists
CCT: 3000K, 4000K, 5000K, 6000K, or market-specific
CRI: Ra70–Ra80 for general outdoor use, Ra90+ for special display or inspection areas
Control: on/off, photocell, motion sensor, 0–10V, DALI, or project-specific
For large outdoor projects, lighting layout support or photometric data is recommended before bulk ordering.
200W LED flood lights provide stronger output and are usually better for larger outdoor areas, higher mounting positions, wider coverage, or longer throw distance. 100W LED flood lights are more suitable for smaller areas, lower mounting heights, and projects where moderate brightness is enough.
| Item | 200W LED Flood Light | 100W LED Flood Light | Best For |
|---|---|---|---|
| Brightness level | Higher outdoor output | Medium outdoor output | 200W for larger spaces; 100W for smaller zones |
| Mounting height | Better for higher or wider coverage | Better for lower mounting positions | Match to pole height and target lux |
| Energy use | Higher power consumption | Lower power consumption | 100W where brightness is enough |
| Heat load | Higher thermal pressure | Lower thermal pressure | 200W needs stronger heat design |
| Common use | parking lots, billboards, yards, sports areas | small yards, signs, entrances, building edges | Depends on site size |
Do not choose 200W only because it sounds stronger. If the area is small or the mounting height is low, 200W may create glare, spill light, and unnecessary energy use.
LED flood lights are designed for wide-area or directional outdoor illumination, while LED high bay lights are designed for overhead lighting in high-ceiling indoor or semi-indoor spaces. A 200W LED flood light is usually used outside, while a high bay light is usually used inside warehouses, factories, and workshops.
| Item | LED Flood Light | LED High Bay Light | Best For |
| Main use | Outdoor area or directional lighting | High-ceiling overhead lighting | Flood lights for outdoor coverage |
| Mounting style | Wall, pole, bracket, ground, facade | Ceiling hook, bracket, pendant, suspended | High bays for warehouses |
| Beam direction | Aimed toward a target area | Downward from ceiling | Flood lights for yards and signs |
| Protection focus | IP rating, sealing, bracket, cable entry | Heat dissipation, optics, mounting safety | Depends on environment |
| Common projects | parking lots, billboards, building exteriors | warehouses, factories, logistics centers | Match to installation type |
For outdoor yards, building exteriors, and signs, choose a flood light. For warehouse ceilings or factory interiors, choose a high bay light with suitable beam angle and mounting hardware.
A 200W LED flood light should provide enough usable lumens to meet the target lux level across the required area. The exact lumen target depends on LED efficiency, beam angle, mounting height, fixture spacing, surface reflection, and light loss factor.
Typical project references:
Parking lots: 75–200 lux depending on safety requirement
Loading yards: 100–300 lux depending on operation
Building entrances: 100–300 lux depending on visibility need
Billboards: depends on sign size, distance, and surface brightness target
Security perimeters: 30–100 lux depending on camera and site design
Sports courts: 200–500 lux or higher depending on activity level
Construction areas: 100–300 lux depending on task level
A basic estimate is:
A basic industrial lighting LED calculator estimate is: Required total lumens = target lux × area in m².
Real projects also need beam spread, mounting height, glare control, pole distance, maintenance factor, and spill-light control. For large areas, layout calculation is better than guessing by wattage.
For buyers choosing between flood and spot lights, narrower beams provide longer throw, while wider beams cover larger nearby areas.
Typical selection guidance:
30°–45°: billboards, signs, facades, columns, and focused lighting
60°: medium-distance outdoor lighting and controlled coverage
90°: general parking lots, yards, and commercial outdoor areas
120°: wide open spaces with lower mounting height
Asymmetric optics: parking edges, wall-mounted lighting, security perimeters, and loading zones
A wide beam can waste light if the target area is narrow or far away. A narrow beam can create bright spots and dark edges if the area is broad. For pole-mounted projects, confirm the beam angle with the real mounting height and fixture spacing.
IP65 is a common starting point for outdoor 200W LED flood lights because it protects against dust and water jets. For harsher sites with stronger rain, washdown, dust, or coastal exposure, IP66 or higher may be required depending on the project.
Typical IP selection guide:
IP54: protected semi-outdoor areas with limited water exposure
IP65: parking lots, building exteriors, yards, signs, and general outdoor areas
IP66: stronger water spray, industrial yards, coastal exposure, or demanding sites
IP67: temporary immersion or special waterproof applications
For outdoor flood lights, do not check only the IP number. Cable glands, gasket fit, glass sealing, screw holes, rear cover, driver compartment, and installation direction are common failure points.
200W LED flood lights usually fail after rain or in humid areas because water enters through cable glands, glass seals, gaskets, screw holes, rear covers, connectors, or damaged housing. Once moisture reaches the driver or PCB, the fixture may flicker, trip, corrode, or fail completely.
Common causes and fixes:
Weak cable gland: use proper waterproof cable entry
Poor gasket fit: improve sealing structure and assembly control
Loose screws: check tightening and housing closure
Wrong installation angle: avoid water pooling near cable entry
Cracked glass or housing: improve material and packaging protection
Non-rated connectors: use outdoor-rated connectors
Condensation: check temperature change and fixture ventilation design
Wrong IP rating: select IP65, IP66, or higher based on exposure
For rainy, coastal, or high-humidity markets, sample approval should include sealing review and installation method, not only brightness testing.
200W LED flood lights flicker because of poor driver quality, unstable input voltage, incompatible dimming controls, loose wiring, water ingress, overloaded circuits, sensor mismatch, or surge damage. Troubleshooting should start with power supply, driver, wiring, and control compatibility.
Common troubleshooting steps:
Measure input voltage at the fixture
Check terminal and cable connections
Confirm driver rating and fixture wattage
Remove dimmer, photocell, or sensor for testing
Check whether water entered the fixture
Inspect grounding and circuit load
Test the flood light on a stable power source
Confirm dimming type: 0–10V, DALI, Triac, PWM, or other
Inspect surge protection after storm events
If flicker appears after rain or cleaning, moisture ingress should be checked first. If flicker appears only with dimming, driver-control compatibility is likely the issue.
200W LED flood lights overheat when heat cannot move away from the LED chips, PCB, driver, or housing efficiently. Common causes include poor heat sink design, weak thermal interface, excessive ambient temperature, blocked airflow, dust buildup, or unsuitable installation position.
Key prevention points:
Use die-cast aluminum or suitable thermal housing
Match 200W power to the fixture’s heat sink capacity
Confirm PCB and thermal pad quality
Keep airflow around the fixture where possible
Avoid installing near heat sources
Confirm ambient temperature range
Clean dust from heat sink surfaces when needed
Use stable drivers with proper thermal protection
Run samples for several hours before approval
Overheating can reduce lumen maintenance, damage drivers, shift color, and increase replacement cost. For high-power flood lights, thermal review is a key sample approval point.
Reduce glare by selecting the right beam angle, aiming direction, mounting height, optical lens, shielding method, CCT, and fixture spacing. Glare control is important because 200W flood lights produce strong output and can disturb drivers, pedestrians, workers, or neighboring properties if aimed poorly.
Practical glare-reduction methods:
Use asymmetric optics where light must move forward
Avoid excessive wattage at low mounting heights
Aim fixtures downward instead of directly outward
Use proper bracket angle and shielding if needed
Choose medium beam instead of overly wide spread where suitable
Avoid very cool CCT where visual comfort matters
Use layout planning for pole-mounted projects
Check local spill-light or dark-sky requirements if applicable
A bright flood light is not enough. The light should reach the target area without wasting output or creating unsafe glare.
Reduce glare by selecting the right beam angle, aiming direction, mounting height, optical lens, shielding method, CCT, and fixture spacing. Glare control is important because 200W flood lights produce strong output and can disturb drivers, pedestrians, workers, or neighboring properties if aimed poorly.
Practical glare-reduction methods:
Use asymmetric optics where light must move forward
Avoid excessive wattage at low mounting heights
Aim fixtures downward instead of directly outward
Use proper bracket angle and shielding if needed
Choose medium beam instead of overly wide spread where suitable
Avoid very cool CCT where visual comfort matters
Use layout planning for pole-mounted projects
Check local spill-light or dark-sky requirements if applicable
A bright flood light is not enough. The light should reach the target area without wasting output or creating unsafe glare.
Before approving a 200W LED flood light sample, inspect lumen output, wattage, beam angle, CCT, CRI, driver stability, waterproof structure, housing strength, bracket quality, cable entry, surge protection, packaging, and label accuracy. The approved sample should become the production reference.
Sample approval checklist:
Measure actual power consumption in W
Check brightness and beam distribution
Confirm CCT and CRI
Test driver stability and flicker
Run the fixture for several hours
Check housing temperature
Inspect glass, lens, reflector, screws, and gasket
Review bracket thickness and adjustment strength
Confirm cable gland and cable length
Test sensor, photocell, or dimming if required
Check IP structure and rear cover sealing
Review carton and inner protection
Confirm logo, product label, and manual
For importers and OEM buyers, sample approval should include both performance and export packaging because heavy flood lights can be damaged during transport.
Provide application area, mounting height, target lux, wattage or lumen target, beam angle, input voltage, CCT, CRI, IP/IK rating, control function, bracket requirement, packaging request, certification need, and destination country. Clear information helps the supplier recommend a suitable 200W LED flood light and quote faster.
Useful details to send:
Application: parking lot, billboard, building exterior, yard, construction site, sports court, security, or loading zone
Area size and mounting height
Pole distance or installation distance if available
Target lux level or brightness expectation
Preferred wattage or lumen output
Beam angle or optical distribution requirement
Input voltage and frequency
CCT and CRI
IP rating, IK rating, and ambient condition
Motion sensor, photocell, dimming, RGB, solar, or emergency need
Bracket type and cable length
Logo, label, manual, and packaging needs
Order quantity and sample quantity
Destination market
Required compliance documents per SKU
Shipping terms: EXW, FOB, CIF, DDP, or door-to-door request
With these details, VST Lighting can provide a more accurate quotation, sample plan, product recommendation, and production schedule for your 200W LED flood light order.










